Monitoring of postural sway with a head-mounted wearable device: effects of gender, participant state, and concussion

24Citations
Citations of this article
88Readers
Mendeley users who have this article in their library.

Abstract

Objective: To assess the utility of a head-mounted wearable inertial motion unit (IMU)-based sensor and 3 proposed measures of postural sway to detect outliers in athletic populations at risk of balance impairments. Methods: Descriptive statistics are used to define a normative reference range of postural sway (eyes open and eyes closed) in a cross-sectional sample of 347 college students using a wireless head-mounted IMU-based sensor. Three measures of postural sway were derived: Linear sway power, eyes closed vs eyes open sway power ratio (Ec/Eo ratio), and weightbearing asymmetry (L-R ratio), and confidence intervals for these measures were calculated. Questionnaires were used to identify potentially confounding state variables. A prospective study of postural sway changes in 47 professional, college, and high school athletes was then carried out in on-field settings to provide estimates of session-to-session variability and the influence of routine physical activity on sway measures. Finally, pre-post-injury changes in sway are measured for a participant who was diagnosed with a concussion. Results: Despite the heterogenous population and sampling environments, well-defined confidence intervals were established for all 3 sway measures. Men demonstrated significantly greater sway than women. Two state variables significantly increased sway: The use of nicotine and prescription medications. In the athletes, session-to-session variability and changes due to routine physical activity remained well within 95% confidence intervals defined by the cross-sectional sample for all 3 sway measures. The increase in sway power following a diagnosed concussion was more than an order of magnitude greater than the increases due to session-to-session variability, physical activity, or other participant state variables. Conclusion: The proposed postural sway measures and head-mounted wearable sensor demonstrate analytic utility for on-field detection of abnormal sway that could be potentially useful when making remove-from-activity and return-to-activity decisions for athletes at risk of impact-induced balance impairments.

Cite

CITATION STYLE

APA

Grafton, S. T., Ralston, A. B., & Ralston, J. D. (2019). Monitoring of postural sway with a head-mounted wearable device: effects of gender, participant state, and concussion. Medical Devices: Evidence and Research, 12, 151–164. https://doi.org/10.2147/MDER.S205357

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free