Impact of the rapid-exchange versus over-the-wire technique on procedural complications of renal artery angioplasty

9Citations
Citations of this article
8Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Purpose: To investigate whether the use of rapid-exchange (RX) systems adds to the safety of percutaneous renal artery procedures compared to the conventional over-the-wire (OTW) technique. Methods: The interventional registry in our department was interrogated to identify patients who underwent plain balloon angioplasty and/or stent implantation for >60% renal artery stenosis and intractable hypertension or decreasing renal function between 1998 and 2004. In this time period, 63 consecutive patients (36 men; mean age 67 years, range 57-80) underwent 78 renal artery angioplasty procedures. The first 46 procedures were done using a transfemoral OTW technique via 7-F sheaths; the following 32 procedures were performed with an RX system via a transfemoral 6-F access. Duration of fluoroscopy, amount of contrast agent, course of serum creatinine, and complications were compared between OTW and RX approaches. Results: Duration of fluoroscopy (median 13.1 versus 11.1 minutes, p=0.099) and primary technical success (94% versus 97%, p=0.64) were not significantly different between the OTW and RX approaches, but significantly less contrast agent was needed with the RX system (median 215 versus 140 mL, p<0.001). Complications, all minor, occurred significantly more often with the OTW (11/46, 24%) compared to the RX system (2/32, 6%; P=0.040) and included misplaced stents, prolonged severe hyper/hypotension, transient renal impairment, and puncture site complications. In particular, the rates of increased serum creatinine within 24 hours were higher in the OTW patients compared to the RX group (20% versus 3%, respectively, for >25% increase [p=0.041] and 9% versus 0% for >50% increase [p=0.087]). Conclusions: Rapid exchange systems seem to add to the safety of percutaneous renal artery interventions. This likely may be due to a variety of causes, including lower doses of contrast medium, shorter duration of fluoroscoov, and smaller device diameters. © 2005 by the International Society of Endovascular Specialists.

Cite

CITATION STYLE

APA

Amighi, J., Sabeti, S., Dick, P., Schlager, O., Ahmadi, R., Minar, E., & Schillinger, M. (2005). Impact of the rapid-exchange versus over-the-wire technique on procedural complications of renal artery angioplasty. Journal of Endovascular Therapy, 12(2), 233–239. https://doi.org/10.1583/04-1467.1

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free