Rapid Quantification of Left Ventricular Function and Mass Using Transoesophageal Three-dimensional Echocardiography: Validation of a Method that uses Long-axis Cutplanes*

35Citations
Citations of this article
12Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Aims: Despite its proven superiority compared to conventional echocardiographic techniques, three-dimensional (3D) echocardiography has not gained widespread acceptance in clinical medicine for the quantification of left ventricular volumes, function and mass. This is mainly due to the large, time-consuming process of data analysis. We sought to validate a new method that enables the accurate quantification of the left ventricle in a clinically acceptable short period of time. Methods and Results: Left ventricular volumes, ejection fraction and mass were determined in 44 patients using 3D echocardiography. The 3D echocardiographic data sets were analysed: (i) using the conventional 'summation of slices' algorithm (slice thickness 5 and 10mm), which is based on the analysis of the 3D reconstructed left ventricle in short-axis cross-sections; and (ii) using the new method which is based on the analysis of the 3D reconstructed left ventricle in long-axis images. In each patient measurements were repeated using 3, 6, 7, 8, 9, 12 and 15 long-axis images. For all volumetric measurements there was a continuous reduction of measurement variability using increasing numbers of long-axis images. The use of more than nine long-axis images for volumes, and eight long-axis images for ejection fraction and mass, did not result in a further reduction of variability. The analysis time for volumes and masses averaged less than 5min for the long-axis method using nine component images, compared to 20-43min for the short-axis method. Conclusion: 3D echocardiography combined with a novel method based on the analysis of long-axis cross-section allows accurate quantification of left ventricular volumes, function and mass in a clinically acceptable short period of time. In the future, the combination of a real-time 3D echocardiographic acquisition technique with this analysis method should have important implications for the introduction of 3D echocardiography in clinical practice. © 2000 The European Society of Cardiology.

Cite

CITATION STYLE

APA

Kühl, H. P., Franke, A., Merx, M., Hoffmann, R., Puschmann, D., & Hanrath, P. (2000). Rapid Quantification of Left Ventricular Function and Mass Using Transoesophageal Three-dimensional Echocardiography: Validation of a Method that uses Long-axis Cutplanes*. European Journal of Echocardiography, 1(3), 213–221. https://doi.org/10.1053/euje.2000.0028

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free