Reducing unplanned extubations in the NICU using lean methodology

28Citations
Citations of this article
138Readers
Mendeley users who have this article in their library.

Abstract

BACKGROUND: Unplanned extubations can lead to iatrogenic injury and have the potential to contribute to serious safety events. We adopted lean methodology to reduce the unplanned extubation rate in a Level 3b NICU. We hypothesized that the use of a rapid-cycle PDSA (plan, do, study, act) initiative would reduce the unplanned extubation rate. METHODS: Baseline unplanned extubation data were collected from November 1, 2012 to June 6, 2014. A voice of the customer survey ascertained perceptions regarding unplanned extubation causes and impact on care. The confidential survey contained 2 open-ended and 4 closed-ended questions and was distributed to a random sample of nurses and respiratory therapists. A fishbone diagram helped to identify opportunities. Six improvements were identified and rolled out in 2 phases using didactic and kinesthetic techniques. Phase 1 standardized the process for turning intubated infants, assessing endotracheal tube (ETT) placement with growth, and communicating tube position with caregivers. Phase 2 addressed respiratory plans of care, correcting ETT migration, establishing ETT re-securement methods, and standardizing position during radiography. The Fisher exact test was used to determine differences in the number of unplanned extubations per 100 intubated days. Descriptive statistics were used to report survey results. Statistical significance was established at P

Cite

CITATION STYLE

APA

Powell, B. M., Gilbert, E., & Volsko, T. A. (2016). Reducing unplanned extubations in the NICU using lean methodology. Respiratory Care, 61(12), 1567–1572. https://doi.org/10.4187/respcare.04540

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free