Abstract
Presented study aimed to determine metals distribution on the quartz fiber filters surface coated with particulate matter by using high and low-volume samplers. The distribution pattern was tested using two different sub-sampling schemes. Each sub-sample was mineralized in the nitric acid in a microwave oven. An analysis was performed by means of atomic absorption spectroscopy with electrothermal atomization GF-AAS technique, and the determined elements were: As, Cd, Pb and Ni. A validation of the analytical procedure was carried out using NIES 28 Urban Aerosols standard reference material. It was assumed that metal is distributed uniformly if its normalized concentrations on a single sub-sample is within ±15% of the mean concentration over the whole filter. The normalized concentrations values exceed this range, indicating a non-homogenous metals distribution. There were no statistically significant differences in metals concentrations between particular sub-samples in the function of its position along the filters diameter.
Author supplied keywords
Cite
CITATION STYLE
Widziewicz, K., Loska, K., & Rogula-Kozłowska, W. (2015). Metals distribution on the surface of quartz fiber filters used for particulate matter collection. Archives of Environmental Protection, 41(4), 3–10. https://doi.org/10.1515/aep-2015-0036