Abstract
The usefulness of numerical modelling of a patient's cardiovascular system is growing in clinical treatment. Understanding blood flow mechanics can be crucial in identifying connections between haemodynamic factors and aortic wall pathologies. OBJECTIVE: This work investigates the haemodynamic parameters of an ascending aorta and ascending aortic aneurysm in humans. METHODS: Two aortic models were constructed from medical images using the SimVascular software. FEM blood flow modelling of cardiac cycle was performed using CFD and CMM-FSI at different vascular wall parameters. RESULTS: The results showed that highest blood velocity was 1.18 m/s in aorta with the aneurysm and 1.9 m/s in healthy aorta model. The largest displacements ware in the aorta with the aneurysm (0.73 mm). In the aorta with the aneurysm, time averaged WSS values throughout the artery range from 0 Pa to 1 Pa. In the healthy aorta, distribution of WSS values changes from 0.3 Pa to 0.6 Pa. CONCLUSIONS: In the case of an ascending aortic aneurysm, the maximum blood velocity was found to be 1.6 times lower than in the healthy aorta. The aneurysm-based model demonstrates a 45% greater wall displacement, while the oscillatory shear index decreased by 30% compared to healthy aortic results.
Author supplied keywords
Cite
CITATION STYLE
Petuchova, A., & Maknickas, A. (2022). Computational analysis of aortic haemodynamics in the presence of ascending aortic aneurysm. Technology and Health Care, 30(1), 187–200. https://doi.org/10.3233/THC-219002