Abstract
This study aimed to clinically and radiographically evaluate the results of guided bone regeneration (GBR) using three-dimensional preformed titanium mesh (3-D-PFTM) for non-contained horizontal defects in 100 consecutive cases. This study involved 100 patients (129 implants) with peri-implant non-contained horizontal defects. The patients were divided into three groups: 3-D-PFTM alone (Group 1), 3-D-PFTM plus cross-linked collagen membrane (Group 2), and 3-D-PFTM plus non-cross-linked collagen membrane (Group 3). Each implant was evaluated radiographically using CBCT at baseline and 6 months postoperatively. At the platform level, the mean horizontal hard tissue gain of all the sites was 3.1 ± 1.3 mm at 6 months postoperatively. The mean rate of mesh exposure was 11.8% in Group 1, 4.2% in Group 2, and 5.0% in Group 3. The mean hard tissue gain rate was 71.0 ± 23.0% in group 1, 84.2 ± 21.5% in group 2, and 84.0 ± 22.9% in group 3. Groups 2 and 3 showed significantly higher hard tissue gain rates than group 1. However, there was no significant difference between the rates in groups 2 and 3. Within the limitations of this study, 3-D-PFTM should be considered as a valuable option for GBR for peri-implant non-contained horizontal defects. The use of an additional resorbable collagen membrane provides additional advantages.
Author supplied keywords
Cite
CITATION STYLE
Choi, I. O., Oh, J. S., Yu, S. J., Kim, B. O., & Lee, W. P. (2021). Retrospective analysis of the effect of three-dimensional preformed titanium mesh on peri-implant non-contained horizontal defects in 100 consecutive cases. Applied Sciences (Switzerland), 11(2), 1–11. https://doi.org/10.3390/app11020872
Register to see more suggestions
Mendeley helps you to discover research relevant for your work.