OPTY-LINE remote-controlled adjustable intramedullary device implantation in open-wedge high tibial osteotomy: A prospective proof-of-concept pilot and comparison with Tomofix fixed-plate device method

5Citations
Citations of this article
34Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Purpose: The objective was to evaluate the clinical and patient-related short- to medium-term performance of the OPTY-LINE nail device for high tibial osteotomy (HTO), comparing a case series of the said device to the established Tomofix fixed-plate device. Patients and Methods: Males with symptomatic medial compartmental osteoarthritis and no serious (co-morbid) knee pathology were followed up, five Tomofix and six OPTY-LINE patients. Patients underwent computed tomography assessment and completed Knee Injury and Osteoarthritis Outcome score (KOOS) and osteotomy surgery patient satisfaction questionnaires, 3 and 6 months post-surgery. A radiologist impression score and a quantitative digital bone density analysis were performed by two independent radiologists. Mann–Whitney U test was applied for inferential statistical tests. Results: At 6 months post-surgery, for Tomofix, the median radiologists’ healing impression score was ‘progressive healing’ versus ‘union virtually complete’ for the OPTY-LINE nail; bone healing quotient was 1.30 (standard deviation (SD) 1.74) versus 1.78 (SD 1.58), p = 0.18. The post-operative absolute surgical accuracy was a mean 12 (7.5) for Tomofix versus 4.1 (2.3) for OPTY-LINE, p = 0.052. At baseline, however, Tomofix patients had more knee symptoms, as determined by KOOS symptom sub-score, when compared to the OPTY-LINE cohort (p = 0.009). Conclusion: This initial, non-randomized, comparative evaluation of the OPTY-LINE device for HTO has produced similar outcomes to patients treated with the established Tomofix device. In particular, the rate of post-surgical bone regeneration and surgical accuracy achieved with the OPTY-LINE device are encouraging. Large-scale randomized controlled studies with longer follow-up are indicated to further evaluate the clinical and patient-related outcome performance for OPTY-LINE.

Cite

CITATION STYLE

APA

Jonker, L., Fallahi, F., Saraswathy, J. J., Edge, J., & Dawson, M. (2019). OPTY-LINE remote-controlled adjustable intramedullary device implantation in open-wedge high tibial osteotomy: A prospective proof-of-concept pilot and comparison with Tomofix fixed-plate device method. Journal of Orthopaedic Surgery, 27(3). https://doi.org/10.1177/2309499019864721

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free