Quantitative estimation of extravascular lung water volume and preload by dynamic 15O-water positron emission tomography

13Citations
Citations of this article
21Readers
Mendeley users who have this article in their library.

Abstract

Aims: Left ventricular filling pressure (preload) can be assessed by pulmonary capillary wedge pressure (PCWP) during pulmonary arterial catheterization (PAC). An emerging method [pulse indexed contour cardiac output (PICCO)] can estimate preload by global end-diastolic volume (GEDV) and congestion as extravascular lung water (EVLW) content. However, no reliable quantitative non-invasive methods are available. Hence, in a porcine model of pulmonary congestion, we evaluated EVLW and GEDV by positron emission tomography (PET). The method was applied in 35 heart failure (HF) patients and 9 healthy volunteers. Methods and results: Eight pigs were studied. Pulmonary congestion was induced by a combination of beta-blockers, angiotensin-2 agonist and saline infusion. PAC, PICCO, computerized tomography, and 15O-H2O-PET were performed. EVLW increased from 521 ± 76 to 973 ± 325 mL (P < 0.001) and GEDV from 1068 ± 170 to 1254 ± 85 mL (P < 0.001). 15O-H2O-PET measures of EVLW increased from 566 ± 151 to 797 ± 231 mL (P < 0.001) and GEDV from 364 ± 60 to 524 ± 92 mL (P < 0.001). Both EVLW and GEDV measured with PICCO and 15O-H2O-PET correlated (r2 = 0.40, P < 0.001; r2 = 0.40, P < 0.001, respectively). EVLW correlated with Hounsfield units (HU; PICCO: r2 = 0.36, P < 0.001, PET: r2 = 0.46, P < 0.001) and GEDV with PCWP (PICCO: r2 = 0.20, P = 0.01, PET: r2 = 0.29, P = 0.002). In human subjects, measurements were indexed (I) for body surface area. Neither EVLWI nor HU differed between chronic stable HF patients and healthy volunteers (P = 0.11, P = 0.29) whereas GEDVI was increased in HF patients (336 ± 66 mL/m2 vs. 276 ± 44 mL/m2, P = 0.01). Conclusion: The present study demonstrates that 15O-H2O-PET can assess pulmonary congestion and preload quantitatively. Hence, prognostic information from 15O-H2O-PET examinations should be evaluated in clinical trials.

Cite

CITATION STYLE

APA

Nielsen, R. R., Sörensen, J., Tolbod, L., Alstrup, A. K. O., Iversen, P., Frederiksen, C. A., … Harms, H. J. (2019). Quantitative estimation of extravascular lung water volume and preload by dynamic 15O-water positron emission tomography. European Heart Journal Cardiovascular Imaging, 20(10), 1120–1128. https://doi.org/10.1093/ehjci/jez038

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free