Standard versus no post-filter ionized calcium monitoring in regional citrate anticoagulation for continuous renal replacement therapy (NPC trial)

8Citations
Citations of this article
16Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background. Current guidelines recommend monitoring of post-filter ionized calcium (pfCa) when using regional citrate anticoagulation during continuous renal replacement therapy (RCA-CRRT) to determine citrate efficiency for the prevention of filter clotting. However, the reliability of pfCa raises the question of whether routine monitoring is required. Reducing the frequency of pfCa monitoring could potentially reduce costs and workload. Our objective was to test the efficacy and safety of no pfCa monitoring among critically ill patients receiving RCA-CRRT. Methods. This study was a non-inferiority randomized controlled trial conducted between January 2021 and October 2021 at King Chulalongkorn Memorial Hospital, Thailand. Critically ill patients who were treated with RCA-CRRT were randomized to receive either standard pfCa monitoring (aiming pfCa level of 0.25–0.35 mmol/L), or no pfCa monitoring, in which a constant rate of citrate infusion was maintained at pre-determined citrate concentrations of 4 mmol/L with blinding of pfCa levels to treating clinicians. The primary outcome was the filter lifespan. Non-inferiority would be demonstrated if the upper limit of the 95% confidence interval (CI) for the difference in filter lifespan between the groups was less than 20 h. Results. Fifty patients were randomized to the standard pfCa monitoring group (n = 25) or no pfCa monitoring group (n = 25). The mean filter lifespan was 54 ± 20 h in the standard pfCa monitoring group and 47 ± 23 h in the no pfCa monitoring group (absolute difference 7.1 h; 95% CI –5.3, 19.5, P = .25). When restricting the analysis to circuits reaching the maximum duration of circuit lifespan at 72 h and clotted filters, the filter lifespan was 61 ± 17 h in the standard pfCa group vs 60 ± 19 h in the no pfCa monitoring group (absolute difference 0.9 h; 95% CI –11.5, 13.4, P = .88). Compared with the no pfCa monitoring group, the standard pfCa monitoring group had a significantly higher mean citrate concentrations (4.43 ± 0.32 vs 4 mmol/L, P

Cite

CITATION STYLE

APA

Thanapongsatorn, P., Sinjira, T., Kaewdoungtien, P., Kusirisin, P., Kulvichit, W., Sirivongrangson, P., … Srisawat, N. (2023). Standard versus no post-filter ionized calcium monitoring in regional citrate anticoagulation for continuous renal replacement therapy (NPC trial). Clinical Kidney Journal, 16(9), 1469–1479. https://doi.org/10.1093/ckj/sfad069

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free