Abstract
Multiple or dual impellers are widely implemented in stirred contactors used in various biological processes like fermentation, water treatment, and pharmaceutical production. The spacing between impellers is considered as a crucial factor in designing of these types of contactors resulting in variation of oxygen mass transfer, mixing time, or power consumption for such biological system. A study of three parts was conducted to characterize the effect of the spacing between impellers on the most important parameters that related to biological contactor performance: oxygen mass transfer coefficient k l a from the gas phase (air) to the liquid phase (water), mixing time, and power consumption for different operating rotational speeds (1.67-3.33 rps) and for three different spacing positions. The used impellers system in the study is a dual impeller system which consists of an inverted and bladed rotated cone (IBRC) and a pitched-blade up-flow propeller (PBPU). The experimental results showed that the shorter spacing (the lower PBPU in a higher position) is more convenient, as the achieved oxygen mass transfer coefficient has showed an improvement in its values with lower mixing time and with a slight alteration in power consumption.
Cite
CITATION STYLE
Issa, H. M. (2016). Power Consumption, Mixing Time, and Oxygen Mass Transfer in a Gas-Liquid Contactor Stirred with a Dual Impeller for Different Spacing. Journal of Engineering (United Kingdom). Hindawi Limited. https://doi.org/10.1155/2016/3954305