Multicenter clinical evaluation of the HeartMate vented electric left ventricular assist system in patients awaiting heart transplantation

470Citations
Citations of this article
133Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Despite advances in heart transplantation and mechanical circulatory support, mortality among transplant candidates remains high. Better ways are needed to ensure the survival of transplant candidates both inside and outside the hospital. Methods: In a prospective, multicenter clinical trial conducted at 24 centers in the United States, 280 transplant candidates (232 men, 48 women; median age, 55 years; range, 11-72 years) unresponsive to inotropic drugs, intra-aortic balloon counterpulsation, or both, were treated with the HeartMate Vented Electric Left Ventricular Assist System (VE LVAS). A cohort of 48 patients (40 men, 8 women; median age, 50 years; range, 21-67 years) not supported with an LVAS served as a historical control group. Outcomes were measured in terms of laboratory data (hemodynamic, hematologic, and biochemical), adverse events, New York Heart Association functional class, and survival. Results: The VE LVAS-treated and non-VE LVAS-treated (control) groups were similar in terms of age, sex, and distribution of patients by diagnosis (ischemic cardiomyopathy, idiopathic cardiomyopathy, and subacute myocardial infarction). VE LVAS support lasted an average of 112 days (range, < 1-691 days), with 54 patients supported for > 180 days. Mean VE LVAS flow (expressed as pump index) throughout support was 2.8 L · min-1 · m-2. Median total bilirubin values decreased from 1.2 mg/dL at baseline to 0.7 mg/dL (P = .0001); median creatinine values decreased from 1.5 mg/dL at baseline to 1.1 mg/dL (P = .0001). VE LVAS-related adverse events included bleeding in 31 patients (11%), infection in 113 (40%), neurologic dysfunction in 14 (5%), and thromboembolic events in 17 (6%). A total of 160 (58%) patients were enrolled in a hospital release program. Twenty-nine percent of the VE LVAS-treated patients (82/280) died before receiving a transplant, compared with 67% of controls (32/48) (P

Cite

CITATION STYLE

APA

Frazier, O. H., Rose, E. A., Dz, M. C., Dembitsky, W., McCarthy, P., Radovancevic, B., … Yakey, J. (2001). Multicenter clinical evaluation of the HeartMate vented electric left ventricular assist system in patients awaiting heart transplantation. Journal of Thoracic and Cardiovascular Surgery, 122(6), 1186–1195. https://doi.org/10.1067/mtc.2001.118274

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free