Abstract
Aim: The study was aimed at esthetic and functional results as well as patient tolerance after reconstruction with reconstruction plate. The follow-up ranged from 1 to 4 years. Materials and methods: A retrospective study of 36 patients who had mandibular reconstruction with AO/ASIF stainless steel reconstruction plates after oncologic resection was evaluated. The indications and postoperative outcomes were studied. Results: At the end of study, 24 of 36 patients (67%) still had the plate in place. Around three (8%) plates were fractured. Nine (25%) plates got exposed leading to surgical intervention. Surgical results were satisfying, particularly when looking at delayed healing or long-term tolerance. Esthetic (79% rated results as good or acceptable) and functional results of this reconstruction were satisfying. Conclusion: We conclude by saying that reconstruction plate provides a solution for safe and rapid mandibular reconstruction for patients with poor prognosis or poor condition. This method also preserves the possibility of secondary reconstruction. Clinical significance: The reconstruction plate may be a good clinical choice for safe and rapid mandibular reconstruction.
Author supplied keywords
Cite
CITATION STYLE
Harsha, G., Reddy, G. K., Talasila, S., Alaam, A., Srinivasulu, S., & Reddy, S. (2012). Mandibular reconstruction using AO/ASIF stainless steel reconstruction plate: A retrospective study of 36 cases. Journal of Contemporary Dental Practice, 13(1), 75–79. https://doi.org/10.5005/jp-journals-10024-1099
Register to see more suggestions
Mendeley helps you to discover research relevant for your work.