Abstract
This paper describes a set of experimental tests on a dual three-phase induction machine for fault-tolerant applications. Both three-phase and six-phase machine operations are considered. Different winding configurations are investigated and compared in case of both open-circuit and short-circuit faults. Experimental tests for each configuration are reported at no-load and under load operating conditions. © 2006 IEEE.
Author supplied keywords
Cite
CITATION STYLE
Alberti, L., & Bianchi, N. (2012). Experimental tests of dual three-phase induction motor under faulty operating condition. IEEE Transactions on Industrial Electronics, 59(5), 2041–2048. https://doi.org/10.1109/TIE.2011.2171175