Abstract
Graphical Abstract start Studi literatur Data uji ukur beban Model simulasi beban Prosentase penurunan THD End Laporkan hasil Hitung nilai R,L, dan C Abstract This research is based on the analysis of the effect of nonlinear load usage on household power consumer of 450 VA to 2200 VA power. Due to the emergence of harmonics on the electrical load of the house that is decreasing the quality of electric power so that the power factor becomes lower. In overcoming this is done designing and simulating the installation of single tuned filter consisting of resistors, inductors, and capacitors to reduce harmonics. The next stage creates the harmonics load modeling and calculates the filter values using Simulink. From the simulation results obtained THD current in each power capacity decreased by 0.27 A, 1.7 A, 0.28 A, 3.05 A. As for THD voltage is also reduced in each variation of power that is 23.67% repaired to 15.87%, 23.33% to 13.93%, 22.89% to 14.73% and 22.27% to 14.41%.
Cite
CITATION STYLE
Harianto, T., Shalahuddin, Y., & Widining K., D. A. (2018). Filter Pasif Single Tuned LC sebagai Kompensator Harmonisa Pada Beban Listrik Rumah Tangga Menggunakan Matlab Simulink. Setrum : Sistem Kendali-Tenaga-Elektronika-Telekomunikasi-Komputer, 7(1), 127. https://doi.org/10.36055/setrum.v7i1.3416