Abstract
In this study, the effect of location of surcharge load on the stability and behavior of the retaining wall under static and dynamic load has been considered. A cantilever retaining wall of 7 m height retained dry sandy soil with 50 kN/m2 surcharge load. Several parameters were taken into account in the numerical analysis, including the horizontal distance (X) from the edge of the wall to the surcharge load expressed as a ratio to the heel width (X/Bh = 0, 0.25, 0.5, 0.75, and 1), as well as the effect of different values of the earthquake's horizontal component (kh = 0.1, 0.2, and 0.3). Lateral earth pressure distribution decreases with increase (X/B h ) in the upper one third of the wall. The effect of surcharge location at the top of the wall disappears at X/B h = 0.25. Under dynamic load, the maximum displacement at the top of the wall is obtained at X/B h = 0.5. It is increased by about 4 times at k h = 0.3. The possibility of sliding increases by about 4.8 times once the k h increases from 0.1 to 0.3. There is a maximum increase in rotation by 2 times at k h = 0.1. In the dynamic case, the differential settlement decreases with increase in X/B h , and increases with the increase in k h .
Author supplied keywords
Cite
CITATION STYLE
Al-Khafaji, R. S., Al-Obaydi, M. A., & Al-Saffar, Q. N. (2023). Effect of surcharge load location on the behavior of cantilever retaining wall. Journal of the Mechanical Behavior of Materials, 32(1). https://doi.org/10.1515/jmbm-2022-0247