Abstract
A retrospective study of 200 cases of subcapital fracture of the neck of the femur treated by sliding nail-plate fixation has been carried out. Failure of fixation within 3 mth occurred in 42 cases (21%). These failures could, in part, be attributed to a combination of the severity of the fracture and various imperfections in technique. The age of the patient and the angle of the nail-plate had no significant effect on the result.
Cite
CITATION STYLE
Brown, T. I. S., & Court-Brown, C. (1979). Failure of sliding nail-plate fixation in subcapital fractures of the femoral neck. Journal of Bone and Joint Surgery - Series B, 61(3), 342–346. https://doi.org/10.1302/0301-620x.61b3.479258