Dosimetric feasibility of stereotactic ablative radiotherapy in pulmonary vein isolation for atrial fibrillation using intensity-modulated proton therapy

3Citations
Citations of this article
17Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Purpose: To evaluate dosimetric properties of intensity-modulated proton therapy (IMPT) for simulated treatment planning in patients with atrial fibrillation (AF) targeting left atrial-pulmonary vein junction (LA-PVJ), in comparison with volumetric-modulated arc therapy (VMAT) and helical tomotherapy (TOMO). Methods: Ten thoracic 4D-CT scans with respiratory motion and one with cardiac motion were used for the study. Ten respiratory 4D-CTs were planned with VMAT, TOMO, and IMPT for simulated AF. Targets at the LA-PVJ were defined as wide-area circumferential ablation line. A single fraction of 25 Gy was prescribed to all plans. The interplay effects from cardiac motion were evaluated based on the cardiac 4D-CT scan. Dose-volume histograms (DVHs) of the ITV and normal tissues were compared. Statistical analysis was evaluated via one-way Repeated-Measures ANOVA and Friedman’s test with Bonferroni’s multiple comparisons test. Results: The median volume of ITV was 8.72cc. All plans had adequate target coverage (V23.75Gy ≥ 99%). Compared with VMAT and TOMO, IMPT resulted in significantly lower dose of most normal tissues. For VMAT, TOMO, and IMPT plans, Dmean of the whole heart was 5.52 ± 0.90 Gy, 5.89 ± 0.78 Gy, and 3.01 ± 0.57 Gy (P < 0.001), mean dose of pericardium was 4.74 ± 0.76 Gy, 4.98 ± 0.62 Gy, and 2.59 ± 0.44 Gy (P < 0.001), and D0.03cc of left circumflex artery (LCX) was 13.96 ± 5.45 Gy, 14.34 ± 5.91 Gy, and 8.43 ± 7.24 Gy (P < 0.001), respectively. However, no significant advantage for one technique over the others was observed when examining the D0.03cc of esophagus and main bronchi. Conclusions: IMPT targeting LA-PVJ for patients with AF has high potential to reduce dose to surrounding tissues compared to VMAT or TOMO. Motion mitigation techniques are critical for a particle-therapy approach.

Cite

CITATION STYLE

APA

Ren, X. Y., He, P. K., Gao, X. S., Zhao, Z. L., Zhao, B., Bai, Y., … Rong, Y. (2021). Dosimetric feasibility of stereotactic ablative radiotherapy in pulmonary vein isolation for atrial fibrillation using intensity-modulated proton therapy. Journal of Applied Clinical Medical Physics, 22(5), 79–88. https://doi.org/10.1002/acm2.13239

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free