Abstract

Aims: Segmental pulmonary vein (PV) isolation by radiofrequency (RF) catheter ablation has become a curative therapy for atrial fibrillation (AF). However, the long procedure time limits the wide application of this procedure. The aim of the current study was to compare a novel ablation technique with a high power output and short application time vs. a conventional technique using a low power output and long application time. Methods and results: The study included 90 consecutive patients (age 53 ± 10 years; 66 men). Segmental PV isolation was performed by irrigated RF catheter ablation in both groups. In the conventional group (Group 1, 45 patients), the power output was limited to 30 W with a target temperature of 50°C and an RF preset duration of 120 s. In the novel group (Group 2, 45 patients), the maximum power output was preset to 45 W, with a target temperature of 55°C and duration of 20 s. In Group 2, a significant reduction in the PV isolation time (127 ± 57 vs. 94 ± 33 min, P < 0.02), mean fluoroscopy time (73 ± 23 vs. 55 ± 16 min, P < 0.001), and radiation dose was observed. According to the application time and number, Group 2 showed a reduction in RF application time, but a higher number of RF applications were required for creation of complete PV isolation. During a mean follow-up of 15 ± 7 months, a total of 74% of patients in Group 1 and 76% of patients in Group 2 demonstrated stable SR. Conclusion: Segmental PV isolation using a high power output and short application time is safe and effective in PV isolation in patients with AF. This technique can significantly reduce the procedure and fluoroscopy time compared with a low-power output technique. © 2006 Oxford University Press.

Cite

CITATION STYLE

APA

Nilsson, B., Chen, X., Pehrson, S., & Svendsen, J. H. (2006). The effectiveness of a high output/short duration radiofrequency current application technique in segmental pulmonary vein isolation for atrial fibrillation. Europace, 8(11), 962–965. https://doi.org/10.1093/europace/eul100

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free