Ten-Year Food and Drug Administration Reporting on Robotic Complications in Gynecologic Surgery

2Citations
Citations of this article
21Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Objective: The United States Food and Drug Administration (FDA) Manufacture and User Device Experience (MAUDE) Database houses reports of deaths, injuries, and malfunctions related to FDA-approved devices. This article evaluates the 10-year statistics from MAUDE related to robotic gynecologic surgery. Materials and Methods: This study is a database analysis. The MAUDE database was queried for events occurring between 2003 and 2012. The following information was abstracted: date of surgery; report date; type of surgery; indication; injury sustained; interventions required; device malfunction; and involvement in legal proceedings. Results: During the 10 years studied, 455 injuries and 177 malfunctions were reported. Reporting increased over time. Gynecologic cases represented 61% of all reported robotic injuries; 81% of these led to legal proceedings. The most common gynecologic procedure resulting in injury was hysterectomy (n=399, 87%). Common complications included ureteral injuries (19%), infections (18%), and small-bowel injuries (16%). This resulted in 435 interventions, most commonly ureteral reimplantation (14%), bowel resection or repair (10%), and vaginal cuff closure (13%). Ninety-three device-related deaths were reported; 30 were associated with gynecologic surgeries. The most common cause of gynecologic procedure-related death was sepsis with or without bowel injury (28%) followed by hemorrhage (18%). Fifty adverse events resulted from 177 robot malfunctions. Conclusions: Reporting of robotic injuries, deaths, and malfunctions to the FDA is steadily increasing; however, as reporting in the MAUDE system is voluntary, the true incidence is unknown. Compulsory reporting would allow identification of absolute risks associated with robotic surgery and lead to improved root-cause analyses.

Cite

CITATION STYLE

APA

Shields, K. M., Minion, L. E., Willmott, L. J., Sumner, D. A., & Monk, B. J. (2015). Ten-Year Food and Drug Administration Reporting on Robotic Complications in Gynecologic Surgery. Journal of Gynecologic Surgery, 31(6), 331–335. https://doi.org/10.1089/gyn.2015.0024

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free