Clinical observations with Closed Loop Stimulation pacemakers in a large patient cohort: The CYLOS routine documentation registry (RECORD)

13Citations
Citations of this article
26Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

AimsClosed Loop Stimulation (CLS) pacemakers couple pacing rate to myocardial contraction dynamics by monitoring unipolar right ventricular impedance on a beat-to-beat basis. The aim of this large-scale registry was to evaluate the safety and efficacy of the CLS therapy under clinical routine conditions.Methods and resultsA total of 706 patients was enrolled in the clinical investigation 'Registry: CYLOS Routine Documentation' (RECORD) at 57 investigational sites in Europe and Hong Kong. Not to interfere with clinical routine and therapeutic decisions of health care providers, the registry was implemented as a part of the standard follow-up schedule. Two follow-ups were conducted within 12 months of enrolment in order to evaluate typical programming of CLS-related parameters, reasons for their later reprogramming, frequency of patient intolerance to CLS, and physicians' satisfaction with medical benefits and technical performance of CLS in each patient. The investigators' medical and technical notes on CLS rated it excellent in ∼80 of patients, poor in 1.4 (medical benefit) or 0.5 (technical performance), and adequate in rest of the patients. Closed Loop Stimulation functionality was not influenced by pacing site variation within the right ventricle (septal, outflow tract) or by advanced heart failure (New York Heart Association classes II-IV). Permanent or temporary CLS deactivation was undertaken for various reasons in 6.2 of patients. Signs of intolerance to CLS or rate-adaptive pacing were reported by 2.3 of patients. Reprogramming of CLS-related parameters was seldom undertaken, with >90 of pacemakers operating with default settings in the long term.ConclusionClinical performance of CLS was very satisfactory in the large cohort studied. © 2012 Published on behalf of the European Society of Cardiology. All rights reserved. © The Author 2012. For permissions please email: journals.permissionsoup.com.

Cite

CITATION STYLE

APA

Lindovská, M., Kameník, L., Pollock, B., Hoenen, S., Bökelmann, T., Spitzer, W., … Frey, A. (2012). Clinical observations with Closed Loop Stimulation pacemakers in a large patient cohort: The CYLOS routine documentation registry (RECORD). Europace, 14(11), 1587–1595. https://doi.org/10.1093/europace/eus062

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free