Surface and intracardiac ECG for discriminating conduction disorders after CoreValve implantation

25Citations
Citations of this article
19Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Transcatheter aortic valve implantation (TAVI) has been developed to minimize operative morbidity and mortality in high-risk symptomatic patients unfit for open surgery. With the proximity of the aortic valve annulus to the conduction system there is, however, an unknown risk of conduction disturbances necessitating monitoring and often cardiac pacing. Materials and methods: We enrolled 50 consecutive patients from January 2007 to 2008 in our prospective evaluation of conduction disturbances measured by surface and intracardiac ECG recordings. Baseline parameters, procedural characteristics as well as twelve-lead surface ECG and intracardiac conduction times were revealed preinterventionally, after TAVI and at 7-day follow-up. Results: TAVI was performed successfully in all patients. During 7 days of follow-up the rate for first-degree AV block raised from 14% at baseline to 44% at day 7 (p<0.001), while rates for type II second- and thirddegree were 0 versus 8% (p<0.001) and 0 versus 12% (p<0.001), respectively. Similarly, the prevalence of new left bundle branch block (LBBB) rose from 2 to 54% (p<0.001). Intracardiac measurements revealed a prolongation of both AH and HV interval from 123.7 ± 41.6 to 136.6 ± 40.5 ms (p<0.001) and from 54.8 ± 11.7 to 71.4 ± 20.0 ms (p<0.001), respectively. Pacemaker implantation at a mean follow-up of 4.8 ± 1.2 days was subsequently performed in 23 patients (46%) due to complete AV block (12%) and type II second-degree AV block (8%) while another 13 patients (26%) received a pacemaker for the combination of new LBBB with marked HV prolongation. The high rate of first-degree AV block was primarily driven by an increase in HV interval. Conclusion: Cardiac conduction disturbances were common in the early experience with CoreValve implantation necessitating close surveillance for at least 1 week. © The Author(s) 2011.

Cite

CITATION STYLE

APA

Akin, I., Kische, S., Schneider, H., Liebold, A., Ortak, J., Bänsch, D., … Ince, H. (2012). Surface and intracardiac ECG for discriminating conduction disorders after CoreValve implantation. Clinical Research in Cardiology, 101(5), 357–364. https://doi.org/10.1007/s00392-011-0400-6

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free