Abstract
A fiber-optic Fabry-Perot hydrogen sensor was developed by measuring the fringe contrast changes at different hydrogen concentrations. The experimental results indicated that the sensing performance with the Pd-Y film was better than that with the Pd film. A fringe contrast with a decrease of 0.5 dB was detected with a hydrogen concentration change from 0% to 5.5%. The temperature response of the sensor was also measured.
Author supplied keywords
Cite
CITATION STYLE
APA
Yu, C., Liu, L., Chen, X., Liu, Q., & Gong, Y. (2015). Fiber-optic Fabry-Perot hydrogen sensor coated with Pd-Y film. Photonic Sensors, 5(2), 142–145. https://doi.org/10.1007/s13320-015-0237-0