Abstract
Purpose: Long treatment sessions are a limitation within magnetic resonance imaging guided adaptive radiation therapy (MRIgART). This work aims for significantly enhancing the delivery efficiency on the magnetic resonance linear accelerator (MR-linac) by introducing dedicated optimization and delivery techniques for volumetric modulated arc therapy (VMAT). VMAT plan and delivery quality during MRIgART is compared with step-and-shoot intensity-modulated radiation therapy (IMRT) for prostate stereotactic body radiation therapy. Methods and Materials: Ten patients with prostate cancer previously treated on a 1.5T MR-linac were retrospectively replanned to 36.25 Gy in 5 fractions using step-and-shoot IMRT and the clinical Hyperion optimizer within Monaco (Hyp-IMRT), the same optimizer with a VMAT technique (Hyp-VMAT), and a research-based optimizer called optimal fluence levels and pseudo gradient descent with VMAT (OFL+PGD-VMAT). The plans were then adapted onto each daily magnetic resonance imaging data set using 2 different optimization strategies to evaluate the adapt-to-position workflow: “optimize weights” (IMRT-Weights and VMAT-Weights) and “optimize shapes” (IMRT-Shapes and VMAT-Shapes). Treatment efficiency was evaluated by measuring optimization time, delivery time, and total time (optimization+delivery). Plan quality was assessed by evaluating organ at risk sparing. Ten patient plans were measured using a modified linac control system to assess delivery accuracy via a gamma analysis (2%/2 mm). Delivery efficiency was calculated as average dose rate divided by maximum dose rate. Results: For Hyp-VMAT and OFL+PGD-VMAT, the total time was reduced by 124 ± 140 seconds (P = .020) and 459 ± 110 seconds (P < .001), respectively, as compared with the clinical Hyp-IMRT group. Speed enhancements were also measured for adapt-to-position with reductions in total time of 404 ± 55 (P < .001) for VMAT-Weights as compared with the clinical IMRT-Shapes group. Bladder and rectum dosimetric volume histogram (DVH) points were within 1.3% or 0.8 cc for each group. All VMAT plans had gamma passing rates greater than 96%. The delivery efficiency of VMAT plans was 89.7 ± 2.7 % compared with 50.0 ± 2.2 % for clinical IMRT. Conclusions: Incorporating VMAT into MRIgART will significantly reduce treatment session times while maintaining equivalent plan quality.
Cite
CITATION STYLE
Snyder, J. E., Fast, M. F., Uijtewaal, P., Borman, P. T. S., Woodhead, P., St-Aubin, J., … Hyer, D. E. (2025). Enhancing Delivery Efficiency on the Magnetic Resonance-Linac: A Comprehensive Evaluation of Prostate Stereotactic Body Radiation Therapy Using Volumetric Modulated Arc Therapy. International Journal of Radiation Oncology Biology Physics, 122(4), 976–985. https://doi.org/10.1016/j.ijrobp.2024.10.028
Register to see more suggestions
Mendeley helps you to discover research relevant for your work.