Polarized light based scheme to monitor column performance in a continuous foam fractionation column

8Citations
Citations of this article
10Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: A polarized light scattering technique was used to monitor the performance of a continuously operated foam fractionation process. The S11and S12parameters, elements of the light scattering matrix, combined together (S11+S12) have been correlated with the bubble size and liquid content for the case of a freely draining foam. The performance of a foam fractionation column is known to have a strong dependence on the bubble size distribution and liquid hold up in foam. In this study the enrichment is used as a metric, representative of foam properties and column performance, and correlated to the S11+S12parameter.Results: Three different superficial gas velocities (6.9, 7.5, and 10.6 cm/min) and four different pH values (4.8, 5.5, 6.5, and 7.5) are tested for the foam fractionation of a dilute solution of bovine serum albumin (0.1 mg/ml). As a result, at scattering angle of 125° the magnitude of S11+S12is higher as the pH increases. When the bubble sizes are small with a larger liquid content, the foam is strongly back scattering resulting in lower values of S11+S12(at 125°) at pH = 4.8. The light scattering data and the enrichment values are measured over a period of 90 minutes and correlated using a linear model. The predictive power of the model was found to be statistically significant.Conclusion: The time average S11+S12shows a direct proportionality with the enrichment value, indicating that polarized light should be a valuable technique for monitoring foam fractionation columns. Additional knowledge of the nature of dependence between foam properties and S11+S12combined with models relating the enrichment to the bubble size and liquid hold up is needed to develop an accurate diagnostics tool for monitoring enrichment utilizing S11+S12measurements. © 2010 Swamy et al; licensee BioMed Central Ltd.

Cite

CITATION STYLE

APA

Swamy, J. N., Crofcheck, C. L., & Mengüç, M. P. (2010). Polarized light based scheme to monitor column performance in a continuous foam fractionation column. Journal of Biological Engineering, 4. https://doi.org/10.1186/1754-1611-4-5

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free