Comparison of short-wavelength blue-light autofluorescence and conventional blue-light autofluorescence in geographic atrophy

38Citations
Citations of this article
40Readers
Mendeley users who have this article in their library.

Abstract

Background/aims To systematically compare the intermodality and inter-reader agreement for two blue-light confocal fundus autofluorescence (FAF) systems. Methods Thirty eyes (21 patients) with a diagnosis of geographic atrophy (GA) were enrolled. Eyes were imaged using two confocal blue-light FAF devices: (1) Spectralis device with a 488 nm excitation wavelength (488-FAF); (2) EIDON device with 450 nm excitation wavelength and the capability for 'colour' FAF imaging including both the individual red and green components of the emission spectrum. Furthermore, a third imaging modality (450-RF image) isolating and highlighting the red emission fluorescence component (REFC) was obtained and graded. Each image was graded by two readers to assess inter-reader variability and a single image for each modality was used to assess the intermodality variability. Results The 95% coefficient of repeatability (1.35 mm 2 for the 488-FAF-based grading, 8.13 mm 2 for the 450-FAF-based grading and 1.08 mm 2 for the 450-RF-based grading), the coefficient of variation (1.11 for 488-FAF, 2.05 for 450-FAF, 0.92 for 450-RF) and the intraclass correlation coefficient (0.994 for 488-FAF, 0.711 for 450-FAF, 0.997 for 450-RF) indicated that 450-FAF-based and 450-RF-based grading have the lowest and highest inter-reader agreements, respectively. The GA area was larger for 488-FAF images (median (IQR) 2.1 mm 2 (0.8-6.4 mm 2)) than for 450-FAF images (median (IQR) 1.0 mm 2 (0.3-4.3 mm 2); p<0.0001). There was no significant difference in lesion area measurement between 488-FAF-based and 450-RF-based grading (median (IQR) 2.6 mm 2 (0.8-6.8 mm 2); p=1.0). Conclusion The isolation of the REFC from the 450-FAF images allowed for a reproducible quantification of GA. This assessment had good comparability with that obtained with 488-FAF images.

Cite

CITATION STYLE

APA

Borrelli, E., Nittala, M. G., Abdelfattah, N. S., Lei, J., Hariri, A. H., Shi, Y., … Sadda, S. R. (2019). Comparison of short-wavelength blue-light autofluorescence and conventional blue-light autofluorescence in geographic atrophy. British Journal of Ophthalmology, 103(5), 610–616. https://doi.org/10.1136/bjophthalmol-2018-311849

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free