Abstract
Objective: To determine the effectiveness of a double-check protocol using Point-of-Care Ultrasound in the management of patients diagnosed with Acute Heart Failure in an Emergency Department. Method: Prospective analytical cross-sectional observational study with patients diagnosed with Acute Heart Failure by the outgoing medical team, who undergo multi-organ ultrasound evaluation including cardiac, pulmonary, and inferior vena cava ultrasound. Results: 96 patients were included. An alternative diagnosis was found in 33% of them. Among the 77% where AHF diagnosis was confirmed, 73.4% had an underlying cause or condition not previously known (Left Ventricular Ejection Fraction less than 40% or moderate-severe valvulopathy). The introduction of the protocol had a clinically relevant impact on 47% of all included patients. Conclusions: The implementation of a double-check protocol using POCUS, including cardiac, pulmonary, and inferior vena cava assessment in patients diagnosed with Acute Heart Failure, demonstrates a high utility in ensuring accurate diagnosis and proper classification of these patients.
Author supplied keywords
Cite
CITATION STYLE
Villén, T., Tung, Y., Llamas, R., Neria, F., Carballo, C., Vázquez, J. L., & Monge, D. (2024). Results of the implementation of a double-check protocol with point-of-care ultrasound for acute heart failure in the emergency department. Ultrasound Journal, 16(1). https://doi.org/10.1186/s13089-024-00373-6