Validation of real-time PCR for laboratory diagnosis of Acanthamoeba keratitis

50Citations
Citations of this article
65Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Confirmation of Acanthamoeba keratitis by laboratory diagnosis is the first step in the treatment of this vision-threatening disease. Two real-time PCR TaqMan protocols (the Rivière and Qvarnstrom assays) were developed for the detection of genus-specific Acanthamoeba DNA but lacked clinical validation. We have adapted these assays for the Cepheid SmartCycler II system (i) by determining their real-time PCR limits of detection and amplification efficiencies, (ii) by determining their ability to detect trophozoites and cysts, and (iii) by testing a battery of positive and negative samples. We also examined the inhibitory effects of a number of commonly used topical ophthalmic drugs on real-time PCR. The results of the real-time PCR limit of detection and amplification efficiency of the Rivière and Qvarnstrom assays were 11.3 DNA copies/10 μl and 94% and 43.8 DNA copies/10 μl and 92%, respectively. Our extraction protocol enabled us to detect 0.7 Acanthamoeba cysts/10 μl and 2.3 Acanthamoeba trophozoites/10 μl by both real-time PCR assays. The overall agreement between the assays was 97.0%. The clinical sensitivity and specificity of both real-time PCR assays based on culture were 100% (7 of 7) and 100% (37 of 37), respectively. Polyhexamethylene biguanide was the only topical drug that demonstrated PCR inhibition, with a minimal inhibitory dilution of 1/640 and an amplification efficiency of 72.7%. Four clinical samples were Acanthamoeba culture negative and real-time PCR positive. Our results indicate that both real-time PCR assays could be used to diagnose Acanthamoeba keratitis. Polyhexamethylene biguanide can inhibit PCR, and we suggest that specimen collection occur prior to topical treatment to avoid possible false-negative results. Copyright © 2008, American Society for Microbiology. All Rights Reserved.

Cite

CITATION STYLE

APA

Thompson, P. P., Kowalski, R. P., Shanks, R. M. Q., & Gordon, Y. J. (2008). Validation of real-time PCR for laboratory diagnosis of Acanthamoeba keratitis. Journal of Clinical Microbiology, 46(10), 3232–3236. https://doi.org/10.1128/JCM.00908-08

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free