Durability tests of ball valve prototype with flowmeter operation

2Citations
Citations of this article
8Readers
Mendeley users who have this article in their library.

Abstract

The results of the investigation of the prototypical ball valve are presented in this article. The innovation of the tested valve is a ball with a built-in measuring orifice. The valve has been subjected to durability tests. Leakage under three temperatures: Ambient,-30°C and +100°C was analyzed. Sealing elements of the valve were tested for roughness and deviation of shape before and after the cycles of operation. Ball valve operation means cycles of open/close. It was planned to perform 1000 cycles at each temperature condition accordingly. Tests of the valve were performed under gas pressure equal to 10 MPa. The research was carried out under the Operational Program "Intelligent Development" (POIR 01.01.01-00-0013/15 "Development of devices for measurement of media flow on industrial trunk-lines".

Author supplied keywords

Cite

CITATION STYLE

APA

Rogula, J., & Romanik, G. (2018). Durability tests of ball valve prototype with flowmeter operation. International Journal of Applied Mechanics and Engineering, 23(1), 235–249. https://doi.org/10.1515/ijame-2018-0014