Focusing light through a multimode fibre (MMF) has attracted significant research interest, mainly driven by the need for miniature endoscopes in biomedicine. In recent years, digital micromirror devices (DMD) have become increasingly popular as a high-speed alternative to liquid-crystal spatial light modulators for light focusing via wavefront shaping based on binary amplitude modulations. To exploit the potentials and limitations of the state-of-the-art DMD-based wavefront shaping methods, in this study, for the first time, we compared four representative, non-holographic and DMD-based methods that are reported so far in literature with the same experimental and simulation conditions, including a real-valued intensity transmission matrix (RVITM)-based algorithm, a complex-valued transmission matrix (TM)-based algorithm, a conditional probability algorithm and a genetic algorithm. We investigated the maximum achievable peak-to-background ratio (PBR) in comparison to theoretical expectations, and further improved the performance of the RVITM-based method. With both numerical simulations and experiments, we found that the genetic algorithm offered the highest PBR but suffered from the lowest focusing speed, while the RVITM-based algorithm provided a comparable PBR to that of the genetic algorithm, and the highest focusing speed.
CITATION STYLE
Zhao, T., Ourselin, S., Vercauteren, T., & Xia, W. (2021). Focusing light through multimode fibres using a digital micromirror device: a comparison study of non-holographic approaches. Optics Express, 29(10), 14269. https://doi.org/10.1364/oe.420718