Abstract
To study the interaction between the transient flow in pipe and the unsteady turbulent flow in turbine, a coupled model of the transient flow in the pipe and three-dimensional unsteady flow in the turbine is developed based on the method of characteristics and the fluid governing equation in the accelerated rotational relative coordinate. The load-rejection process under the closing of guide vanes of the hydraulic power plant is simulated by the coupled method, the traditional transient simulation method and traditional three-dimensional unsteady flow calculation method respectively and the results are compared. The pressure, unit flux and rotation speed calculated by three methods show a similar change trend. However, because the elastic water hammer in the pipe and the pressure fluctuation in the turbine have been considered in the coupled method, the increase of pressure at spiral inlet is higher and the pressure fluctuation in turbine is stronger. © Published under licence by IOP Publishing Ltd.
Cite
CITATION STYLE
Huang, W. D., Fan, H. G., & Chen, N. X. (2012). Transient simulation of hydropower station with consideration of three-dimensional unsteady flow in turbine. In IOP Conference Series: Earth and Environmental Science (Vol. 15). https://doi.org/10.1088/1755-1315/15/5/052003
Register to see more suggestions