Evaluation of objective and subjective binocular ocular refraction with looking in type

3Citations
Citations of this article
14Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: This study aimed to compare the results of the Chronos binocular/monocular refraction system, that measures objective and subjective ocular refraction in one unit, to objective findings obtained from a conventional autorefractometer and a conventional subjective ocular refraction using a trial-frame in real space. Methods: Twenty-eight healthy volunteers (21.2 ± 1.5 years old) were included in this study. Objective ocular refraction was measured using two tests: the Chronos binocular/monocular refraction system under binocular conditions and a conventional autorefractometer under monocular conditions. Subjective ocular refraction was measured using three tests: Chronos binocular/monocular refraction system under binocular, monocular conditions, and trial-frame in the real space under monocular conditions. The measurement distance was set to 5.0 m for each test. All ocular refractions were converted into spherical equivalents (SEs). Results: The objective SE was significantly more negative with Chronos binocular/monocular refraction system under binocular condition (− 4.08 ± 2.76 D) than with the conventional autorefractometer under monocular condition (− 3.85 ± 2.66 D) (P = 0.002). Although, the subjective SE was significantly more negative with Chronos binocular/monocular refraction system under binocular condition (− 3.55 ± 2.67 D) than with the trial-frame in the real space under monocular condition (− 3.33 ± 2.75 D) (P = 0.002), Chronos binocular/monocular refraction system under monocular condition (− 3.17 ± 2.57 D) was not significantly different from that in trial-frame in real space under monocular condition (P = 0.33). Conclusion: These findings suggest that the Chronos binocular/monocular refraction system, which can complete both objective and subjective ocular refraction tests in a single unit, is suitable for screening ocular refraction, although it produces slightly more myopic results. Furthermore, subjective ocular refraction testing accuracy in Chronos binocular/monocular refraction system can be equivalent to trial-frame in real-space testing by switching from binocular to monocular condition.

Cite

CITATION STYLE

APA

Fukushima, M., Hirota, M., Yukimori, T., Hayashi, A., Hirohara, Y., Saika, M., & Matsuoka, K. (2024). Evaluation of objective and subjective binocular ocular refraction with looking in type. BMC Ophthalmology, 24(1). https://doi.org/10.1186/s12886-024-03449-y

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free