Fatigue crack growth characteristics of a Ti-15V-3Cr-3Sn-3Al alloy with variously aged conditions

3Citations
Citations of this article
12Readers
Mendeley users who have this article in their library.

Abstract

In this study, the fatigue crack growth rate (FCGR) of a Ti-15V-3Cr-3Al-3Sn (Ti-15-3) alloy, which was aged at a temperature range of 371 to 593°C, was measured in air at room temperature. The specimen aged at 371°C showed clear serrations in the crack growth curve at a stress ratio (R) of 0.1, and it also exhibited a larger Paris law gradient than the other aged specimens at R = 0.5. The peak-aged (426°C aged) specimen had the highest FCGR of the specimens, regardless of the stress ratio. A gradual decrease in the FCGRs with increasing aging temperature, from 482 to 593°C, was observed for the over-aged specimens. Cleavage-like fracture was more likely to occur in the under- and peak-aged specimens as compared to the transgranular fatigue in the over-aged specimens. It seemed that the coarse α platelets with lowered hardness in the over-aged specimens resulted in a higher resistance to fatigue crack growth in the Ti-15-3 alloy. © 2013 The Japan Institute of Metals.

Cite

CITATION STYLE

APA

Tsay, L. W., Chang, S. T., & Chen, C. (2013). Fatigue crack growth characteristics of a Ti-15V-3Cr-3Sn-3Al alloy with variously aged conditions. Materials Transactions, 54(3), 326–331. https://doi.org/10.2320/matertrans.M2012349