Virtual non-contrast images from dual-energy CT angiography of the abdominal aorta and femoral arteries: comparison with true non-contrast CT images

9Citations
Citations of this article
12Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Objectives: To assess whether virtual non-contrast (VNC) computed tomography (CT) images acquired from dualenergy CT (DECT) have sufficient image quality to replace true non-contrast (TNC) CT images in CT angiography (CTAG). Methods: This study enrolled 63 consecutive patients who underwent a CTAG that included a single-energy noncontrast scan, followed by a post-contrast DECT scan. Comparison of attenuation and noise between TNC and VNC images was made by drawing circular regions of interest (ROI) on a picture archiving and communication system (PACS) workstation within the aortic lumen at the levels of the renal arteries, the aortic bifurcation and right femoral artery. Mean attenuation and image noise (one standard deviation) were registered in Hounsfield units (HU). The VNC images were subjectively evaluated for artifacts such as subtraction of calcifications or architectural distortion based on TNC image as a standard of reference. Results: Most attenuations of the VNCs were higher than TNC, except right femoral artery of reader 2. Most image noises of TNC were higher than VNC, except abdominal aorta in reader 1. In qualitative image analysis, mean scores of VNC according to the 5-point scale were 3.68 and 3.63 (reader 1 and reader 2, respectively) which mean good to excellent to diagnose. Conclusion: HUs and VNC image noises are different from TNC images in CTAG. VNC images have sufficient image quality to replace TNC images in the diagnosis of calcific lesions. Advances in knowledge: VNC images acquired from DECT have image quality adequate to replace TNC images in the diagnosis of the calcific lesion on the CTAG. VNC images based on DECT can avoid excessive and unnecessary patient exposure to radiation during CTAG.

Cite

CITATION STYLE

APA

Lee, M. H., Park, H. J., Kim, J. N., Kim, M. S., Hong, S. W., Park, J. H., & Kang, C. H. (2022). Virtual non-contrast images from dual-energy CT angiography of the abdominal aorta and femoral arteries: comparison with true non-contrast CT images. British Journal of Radiology, 95(1138). https://doi.org/10.1259/bjr.20220378

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free