Abstract

Purpose: To validate a novel, real-time, steady-state free precession (SSFP), single-breathhold technique for the assessment of left ventricular (LV) and right ventricular (RV) function in heart failure patients. Materials and Methods: A total of 20 heart failure patients (mean age 59 ± 17 years) underwent scanning with our new, real-time, spiral SSFP sequence in which each cardiac phase was acquired in 118 msec at a resolution of 1.8 × 1.8 mm. Each cardiac slice (1-cm thick) was automatically advanced based on a cardiac trigger, allowing complete coverage of the heart in a single breathhold. The patients also underwent LV and RV assessment with the gold standard: multiple breathhold, cardiac-gated, segmented k-space strategy. LV and RV end-systolic volume (ESV) and end-diastolic volume (EDV) and LV mass were compared between the two imaging techniques. Results: The new real-time strategy was highly concordant with the gold standard technique in the assessment of LVEDV (r = 0.98), LVESV (r = 0.98), RVESV (r = 0.86), RVEDV (r = 0.91), LVMASS (r = 0.95), RVEF (r = 0.70), and LVEF (r = 0.94). The mean bias (95% confidence interval [CI]) for each parameter is LVEDV: 10.6 cc (cm3) (3.8-17.4 cc), LVESV: -0.8 cc (-5.3 to 3.7 cc), RVEDV: 3.7 cc (-5.6 to 13.2 cc), RVESV: -3.1 cc (-11.1 to 4.9 cc), LVMASS: 26 g (12.4-39.8 g), RVEF: -2.9% (1.3 to -7.2 %), LVEF: 1.9% (5 to -1.1%). In addition, data acquisition was only nine ± two seconds with the real-time strategy vs. 312 ± 41 seconds for the standard technique. Conclusion: In patients with heart failure, real-time, spiral SSFP allows rapid and accurate assessment of RV and LV function in a single-breath hold. Using the same strategy, increased temporal resolution will allow real-time assessment of cardiac wall motion during stress studies. © 2005 Wiley-Liss, Inc.

Author supplied keywords

Cite

CITATION STYLE

APA

Narayan, G., Nayak, K., Pauly, J., & Hu, B. (2005). Single-breathhold, four-dimensional, quantitative assessment of LV and RV function using triggered, real-time, steady-state free precession MRI in heart failure patients. Journal of Magnetic Resonance Imaging, 22(1), 59–66. https://doi.org/10.1002/jmri.20358

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free