Implantable cardioverter defibrillator and cardiac resynchronization treatment in people with type 2 diabetes: a comparison with age- and sex matched controls from the general population

0Citations
Citations of this article
2Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: Increased risk of severe tachyarrhythmias is reported in patients with type 2 diabetes mellitus (T2DM). The aim of this study was to explore if treatment with cardiac implantable electronic device (CIED) such as implantable cardioverter defibrillator (ICD), cardiac resynchronization therapy- pacemaker and -defibrillator (CRT-P/CRT-D) differed in patients with vs. without T2DM. A secondary aim was to identify patient characteristics indicating an increased CIED treatment. Method: 416 162 adult patients with T2DM from the Swedish National Diabetes Registry and 2 081 087 controls from the Swedish population, matched for age, sex and living area, were included between 1/1/1998 and 31/12/2012 and followed until 31/12/2013. They were compared regarding prevalence of ventricular tachycardia (VT) at baseline and the risk of receiving a CIED during follow-up. Multivariable Cox regression analysis was performed to estimate the risk of CIED-treatment and factors identifying patients with such risk. Results: Ventricular fibrillation (VF) (0.1% vs 0.0004%) and (VT) (0.2% vs. 0.1%) were more frequent among patients with T2DM compared to controls. CIED-treatment was significantly increased in patients with T2DM both in unadjusted and adjusted analyses. HR and 95% CI, after adjustment for sex, age, marital status, income, education, country of birth, coronary artery disease and congestive heart failure, were 1.32 [1.21–1.45] for ICD, 1.74 [1.55–1.95] for CRT-P and 1.69 [1.43–1.99] for CRT-D. Blood-pressure and lipid lowering therapies were independent risk factors associated to receiving CIED, while female sex was protective. Conclusions: Although the proportion of VT/VF was low, patients with T2DM had a higher prevalence of these conditions and increased risk for treatment with CIED compared to controls. This underlines the importance of recognizing that T2DM patients have an increased need of CIED.

Cite

CITATION STYLE

APA

Rautio, E., Gadler, F., Gudbjörnsdottir, S., Franzén, S., Rydén, L., Savarese, G., … Mellbin, L. G. (2024). Implantable cardioverter defibrillator and cardiac resynchronization treatment in people with type 2 diabetes: a comparison with age- and sex matched controls from the general population. Cardiovascular Diabetology, 23(1). https://doi.org/10.1186/s12933-023-02084-z

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free