Recovery of serum cholesterol predicts survival after left ventricular assist device implantation

12Citations
Citations of this article
27Readers
Mendeley users who have this article in their library.

Abstract

Background - Advanced systolic heart failure is associated with myocardial and systemic metabolic abnormalities, including low levels of total cholesterol and low-density lipoprotein. Low cholesterol and low-density lipoprotein have been associated with greater mortality in heart failure. Implantation of a left ventricular assist device (LVAD) reverses some of the metabolic derangements of advanced heart failure. Methods and Results - A cohort was retrospectively assembled from 2 high-volume implantation centers, totaling 295 continuous-flow LVAD recipients with ≥2 cholesterol values available. The cohort was predominantly bridge-to-transplantation (67%), with median age of 59 years and 49% ischemic heart failure cause. Total cholesterol, low-density lipoprotein, high-density lipoprotein, and triglyceride levels all significantly increased after LVAD implantation (median values from implantation to 3 months post implantation 125-150 mg/dL, 67-85 mg/dL, 32-42 mg/dL, and 97-126 mg/dL, respectively). On Cox proportional hazards modeling, patients achieving recovery of total cholesterol levels, defined as a median or greater change from pre implantation to 3 months post-LVAD implantation, had significantly better unadjusted survival (hazard ratio, 0.445; 95% confidence interval, 0.212-0.932) and adjusted survival (hazard ratio, 0.241; 95% confidence interval, 0.092-0.628) than those without cholesterol recovery after LVAD implantation. The continuous variable of total cholesterol at 3 months post implantation and the cholesterol increase from pre implantation to 3 months were also both significantly associated with survival during LVAD support. Conclusions - Initiation of continuous-flow LVAD support was associated with significant recovery of all 4 lipid variables. Patients with a greater increase in total cholesterol by 3 months post implantation had superior survival during LVAD support.

Cite

CITATION STYLE

APA

Vest, A. R., Kennel, P. J., Maldonado, D., Young, J. B., Mountis, M. M., Naka, Y., … Schulze, P. C. (2016). Recovery of serum cholesterol predicts survival after left ventricular assist device implantation. Circulation: Heart Failure, 9(9). https://doi.org/10.1161/CIRCHEARTFAILURE.115.002881

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free