Abstract

Background: BlaAFM-1 (GenBank Accession No. 143105.1) is a new B1 subclass metallo-β-lactamase gene discovered by our group, and isolated from an Alcaligenes faecalis plasmid that renders carbapenem antibiotics ineffective. In this study, we generated a fast and reliable assay for blaAFM-1 detection. Methods: We designed optimum loop-mediated isothermal amplification (LAMP) primers and constructed a recombinant plasmid AFM-1 to specifically detect blaAFM-1. Optimal LAMP primers were used to assess sensitivity of the recombinant plasmid AFM-1 and blaAFM-1-supplemented samples (simulated sputum and simulated feces). Fifty two samples, without blaAFM-1, were used to assess LAMP real-time assay specificity; these samples were verified by conventional PCR and sequencing for the absence of blaAFM-1. Three hundred clinical Gram-negative carbapenem-resistant strains were tested by LAMP assay for strains carrying blaAFM-1, which were confirmed by conventional PCR and Sanger sequencing. We calculated the sensitivity and its 95% confidence interval (95% CI), specificity and its 95% CI, and predictive values of the LAMP assay and conventional PCR/sequencing by investigating positive and negative clinical strains. Results: The lowest limit of detection for the recombinant plasmid AFM-1 and blaAFM-1-supplemented samples (in both simulated sputum and simulated feces) was 101 copies/reaction. All amplification curves of the 52 blaAFM-1-free bacteria strains were negative, suggesting the LAMP assay had excellent specificity for detecting blaAFM-1. Among the 300 clinical strains, eight were positive for blaAFM-1 using LAMP. These LAMP results were consistent with conventional PCR and Sanger sequencing data. As with conventional PCR/sequencing, the LAMP method exhibits 100% sensitivity (95% CI 59.8–100%) and 100% specificity (95% CI 98.4–100%) for blaAFM-1 detection. The LAMP assay is also time-efficient (1 h) for blaAFM-1 detection. Conclusions: We established a new LAMP assay with high sensitivity and specificity to detect the novel B1-β-lactamase gene, blaAFM-1.

Cite

CITATION STYLE

APA

Qin, Y., Duan, X., Peng, Y., & Rui, Y. (2021). Rapid detection of a novel B1-β-lactamase gene, blaAFM-1 using a loop-mediated isothermal amplification (LAMP) assay. Annals of Clinical Microbiology and Antimicrobials, 20(1). https://doi.org/10.1186/s12941-021-00486-z

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free