Although extensive research has been conducted, understanding the exact phenomena occurring during the operation of polymer electrolyte fuel cells (PEFCs) remains difficult. This research attempted to identify new reasons for the reduced performance of PEFC using an imaging technique. To begin with, H+ and OH− indicator sensors, which display red, blue, and green values (RGB) using digital microscopes, are developed and attached to each electrode of a membrane electrode assembly to enable quantitative analysis of ion generation. The proposed reaction in the fuel cell can be confirmed, and various reactions occurring in the electrode can be examined using this approach. In particular, H+ is generated at the anode and cathode of the anion exchange membrane fuel cell, which is found to be a major cause of performance deterioration.

Cite

CITATION STYLE

APA

Woo, S. H., Lee, N. J., Yook, S. H., Kim, H. S., Choi, J., Kim, J. H., … Kim, H. J. (2023). Indicator Sensor Development and Fuel Cell Degradation Imaging. Advanced Functional Materials, 33(46). https://doi.org/10.1002/adfm.202305231