Analysis of the Application Value of Different Esophagography Techniques in the Diagnosis of H-Type Tracheoesophageal Fistula in Neonates

3Citations
Citations of this article
11Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Objective. The study aimed to analyse the detection rates of the triple-lumen double-balloon catheter technique and conventional esophagography in diagnosing H-Type tracheoesophageal fistula (H-TEF) in neonates. Methods. The data of 8 neonates diagnosed with H-TEF by surgery in the researchers' hospital between January 2015 and January 2022 were collected. We compared the detection (true positive) rates of H-TEF by the triple-lumen double-balloon catheter technique, conventional esophagography, and multidetector row spiral CT. Results. Before surgery, conventional esophagography was applied in all 8 cases, of which the H-TEF diagnosis was confirmed in 5 cases and TEF was suspected in 3 cases. The triple-lumen double-balloon catheter technique was employed in 5 cases, of which 4 were confirmed with H-TEF and 1 was suspected with TEF. Multidetector row spiral CT was performed in 4 cases, and 1 case was confirmed with H-TEF, while no fistula was observed in the other 3 cases. The triple-lumen double-balloon catheter technique yielded a 100% detection rate, while conventional esophagography revealed a 62.5% rate and multidetector row spiral CT showed a 25% rate. By comparative analysis, the true positive rates (TPRs) of the triple-lumen double-balloon catheter technique and conventional esophagography were not significantly different (P=0.118). No significant differences were recorded in TPRs between conventional esophagography and multidetector row spiral CT (P=0.221). However, the triple-lumen double-balloon catheter technique had a significantly higher TPR than multidetector row spiral CT (P=0.118). Conclusion. To diagnose congenital H-TEF in neonates, conventional esophagography is a highly valuable yet inconsistently reliable method and the diagnostic value of CT is relatively limited. The triple-lumen double-balloon catheter technique boasts a significantly valuable application for H-TEF diagnosis. Being simple, economical, and effective, it barely requires state-of-The-Art facilities, and no complications have occurred during its clinical practice. These advantages justify a possible wider application of the triple-lumen double-balloon catheter technique in clinical practice.

Cite

CITATION STYLE

APA

Deng, K., & Luo, L. (2022). Analysis of the Application Value of Different Esophagography Techniques in the Diagnosis of H-Type Tracheoesophageal Fistula in Neonates. Evidence-Based Complementary and Alternative Medicine, 2022. https://doi.org/10.1155/2022/7264343

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free