Highly sensitive diode-based micro-pirani vacuum sensor with low power consumption

11Citations
Citations of this article
14Readers
Mendeley users who have this article in their library.

Abstract

Micro-Pirani vacuum sensors usually operate at hundreds of microwatts, which limits their application in battery-powered sensor systems. This paper reports a diode-based, low power consumption micro-Pirani vacuum sensor that has high sensitivity. Optimizations to the micro-Pirani vacuum sensor were made regarding two aspects. On the one hand, a greater temperature coefficient was obtained without increasing power consumption by taking advantage of series diodes; on the other hand, the sensor structure and geometries were redesigned to enlarge temperature variation. After that, the sensor was fabricated and tested. Test results indicated that the dynamic vacuum pressure range of the sensor was from 10 −1 to 10 4 Pa when the forward bias current was as low as 10 µA with a power consumption of 50 µW. Average sensitivity was up to 90 µV/Pa and the sensitivity of unit power consumption increased to 1.8 V/W/Pa. In addition, the sensor could also work at a greater forward bias current for better sensor performance.

Cite

CITATION STYLE

APA

Wei, D., Fu, J., Liu, R., Hou, Y., Liu, C., Wang, W., & Chen, D. (2019). Highly sensitive diode-based micro-pirani vacuum sensor with low power consumption. Sensors (Switzerland), 19(1). https://doi.org/10.3390/s19010188