Performance characteristics of a carbon isotope ratio method for detecting doping with testosterone based on urine diols: Controls and athletes with elevated testosteone/epitestosterone ratios

95Citations
Citations of this article
41Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Background: Carbon isotope ratio methods are used in doping control to determine whether urinary steroids are endogenous or pharmaceutical. Methods: Gas chromatography-combustion-isotope ratio mass spectrometry (GC-C-IRMS) was used to determine the δ13C values for 5β-androstane-3α,17β-diyl diacetate (5βA), 5α-androstane-3α,17β-diyl diacetate (5αA), and 5β-pregnane-3α,20α-diyl diacetate (5βP) in a control group of 73 healthy males and 6 athletes with testosterone/epitestosterone ratios (T/E) >6. Results: The within-assay precision SDs for 5βA, 5αA, and 5βP were ± 0.27‰, ± 0.38‰, and ± 0.28‰, respectively. The between-assay precision SDs ranged from ± 0.40‰ to ± 0.52‰. The system suitability and batch acceptance scheme is based on SDs. For the control group, the mean δ13C (SD) values were -25.69‰ (± 0.92%), -26.35‰ (± 0.68‰), and -24.26‰ (± 0.70‰), for 5βA, 5αA, and 5βP, respectively. 5βP was greater than 5βA and 5αA (P <0.01), and 5βA was greater than 5αA (P <0.01). The means-3 SD were -28.46‰, -28.39‰, and -26.37‰ for 5βA, 5αA, and 5βP, respectively. The maximum difference between 5βP and 5βA was 3.2‰, and the maximum 5βA/5βP was 1.13. Three athletes with chronically elevated T/Es had δ13C values consistent with testosterone administration and three did not. Conclusions: This GC-C-IRMS assay of urine dials has low within- and between-assay SDs; therefore, analysis of one urine sample suffices for doping control. The means, SDs, ±3 SDs, and ranges of δ13C values in a control group are established. In comparison, testosterone users have low 5βA and 5αA, large differences between 5βA or 5αA and 5βP, and high 5βA/5βP and 5αA/5βP ratios. © 2001 American Association for Clinical Chemistry.

Cite

CITATION STYLE

APA

Aguilera, R., Chapman, T. E., Starcevic, B., Hatton, C. K., & Catlin, D. H. (2001). Performance characteristics of a carbon isotope ratio method for detecting doping with testosterone based on urine diols: Controls and athletes with elevated testosteone/epitestosterone ratios. Clinical Chemistry, 47(2), 292–300. https://doi.org/10.1093/clinchem/47.2.292

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free