[Efficacy of patient skin dose reduction by a compensating filter through of irradiation field overlaps on the area during percutaneous coronary intervention].

0Citations
Citations of this article
6Readers
Mendeley users who have this article in their library.

Abstract

Our study was involved with entrance surface dose reduction and irradiation field by the filter use of PCI, and insertion in place of an effective compensating filter to maximize entrance surface dose reduction, which we verified. The radiation dosimetry put a 6cc ion chamber on the back side of the thorax phantom, and changed the filter of the four corners (a: upper left, b: upper right, c: lower right, d: lower left) of the monitor confirmed with fluoroscopy [(0) no filter, (1) one filter, (2) two filters]. The angle of C arm was assumed to be eight directions and 0 degrees adopted by this hospital. It was compared with a corrective rate of which one was no filter. Next, the presence of filter and irradiation field overlaps on the area in monitor in the angle of C arm was verified by this hospital's classic example. As for corrective rate, (1) becomes 0.41 and (2) become 0.25 at fluoroscopy, (1) becomes 0.26 and (2) become 0.16 at exposure. Irradiation field overlaps on the area (+) compensating filter (-) was many with d of RAO/CAU, a of RAO and c of CAU at left CAG, c of LAO at right CAG, b of LAO/CRA (left CAG), b of CRA (right CAG) and a and d of RAO (right CAG) at both CAG. Irradiation field overlaps on the area (+) compensating filter (+) was many with b of CRA at left CAG, a of LAO/CRA at right CAG, b of CRA (left CAG) and b of RAO (right CAG) at both CAG. When the compensating filter is used the entrance surface dose reduction effect was great. If automatic exposure control protects the part of irradiation field overlaps on the area in the range without operating excessively, the radiological risk can be reduced, and it is conceivable as useful clinical setting.

Cite

CITATION STYLE

APA

Yamasaki, H., Nakahara, M., Yamaguchi, S., Yamamoto, N., Miyagawa, T., Hirose, E., & Takenaka, T. (2011). [Efficacy of patient skin dose reduction by a compensating filter through of irradiation field overlaps on the area during percutaneous coronary intervention]. Nihon Hoshasen Gijutsu Gakkai Zasshi, 67(12), 1565–1573. https://doi.org/10.6009/jjrt.67.1565

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free