Closed-loop insulin delivery using a subcutaneous glucose sensor and intraperitoneal insulin delivery: Feasibility study testing a new model for the artificial pancreas

172Citations
Citations of this article
105Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

OBJECTIVE - Attempts to build an artificial pancreas by using subcutaneous insulin delivery from a portable pump guided by an subcutaneous glucose sensor have encountered delays and variability of insulin absorption. We tested closed-loop intraperitoneal insulin infusion from an implanted pump driven by an subcutaneous glucose sensor via a proportional-integralderivative (PID) algorithm. RESEARCH DESIGN AND METHODS - Two-day closed-loop therapy (except for a 15-min premeal manual bolus) was compared with a 1-day control phase with intraperitoneal open-loop insulin delivery, according to randomized order, in a hospital setting in eight type 1 diabetic patients treated by implanted pumps. The percentage of time spent with blood glucose in the 4.4-6.6 mmol/l range was the primary end point. RESULTS - During the closed-loop phases, the mean ± SEM percentage of time spent with blood glucose in the 4.4-6.6 mmol/l range was significantly higher (39.1 ± 4.5 vs. 27.7 ± 6.2%, P = 0.05), and overall dispersion of blood glucose values was reduced among patients. Better closed-loop glucose control came from the time periods excluding the two early postprandial hours with a higher percentage of time in the 4.4-6.6 mmol/l range (46.3± 5.3 vs. 28.6 ± 7.4, P = 0.025) and lower mean blood glucose levels (6.9 ± 0.3 vs. 7.9 ± 0.6 mmol/l, P = 0.036). Time spent with blood glucose <3.3 mmol/l was low and similar for both investigational phases. CONCLUSIONS - Our results demonstrate the feasibility of intraperitoneal insulin delivery for an artificial β-cell and support the need for further study. Moreover, according to a semiautomated mode, the features of the premeal bolus in terms of timing and amount warrant further research. © 2010 by the American Diabetes Association.

Cite

CITATION STYLE

APA

Renard, E., Place, J., Cantwell, M., Chevassus, H., & Palerm, C. C. (2010). Closed-loop insulin delivery using a subcutaneous glucose sensor and intraperitoneal insulin delivery: Feasibility study testing a new model for the artificial pancreas. Diabetes Care, 33(1), 121–127. https://doi.org/10.2337/dc09-1080

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free