Abstract
Based on remote sensing, geological data, geomorphologic analysis, and field observations, we determine the fault system which is a potential source of earthquakes in Hoa-Binh reservoir. It is the sub-meridian fault system composed of fault segments located in the central part of the eastern and western flanks of the Quaternary Hoa-Binh Graben: the Hoa-Binh 1 fault is east-dipping (75-80), N-S trending, 4 km long, situated in the west of the Hoa-Binh Graben, and the Hoa-Binh 2 is a west-dipping (75-80), N-S trending; 8.4 km long fault, situated in the east of the Hoa-Binh Graben. The slip rate of normal fault in Hoa-Binh hydropower dam was estimated at 0.3-1.1 mm/yr. The Maximum Credible Earthquake (MCE) and Peak Ground Acceleration (PGA) in the Hoa-Binh hydropower dam have been assessed. The estimated MCE of HB.1 and HB.2 is 5.6 and 6.1 respectively, and the maximum PGA at Hoa-Binh dam is 0.30 g and 0.40 g, respectively. The assessment of seismic hazard in Hoa-Binh reservoir is a typical example of seismic hazards of a large dam constructed in an area of low seismicity and lack of law of seismic attenuation. © 2013 Versita Warsaw and Springer-Verlag Wien.
Author supplied keywords
Cite
CITATION STYLE
Trinh, P. T., Vinh, H. Q., Huong, N. V., & Liem, N. V. (2013). Active fault segmentation and seismic hazard in Hoa-Binh reservoir, Vietnam. Central European Journal of Geosciences, 5(2), 223–235. https://doi.org/10.2478/s13533-012-0128-5
Register to see more suggestions