Performance evaluation of Biofire Film Array Respiratory Panel 2.1 for SARS-CoV-2 detection in a pediatric hospital setting

1Citations
Citations of this article
10Readers
Mendeley users who have this article in their library.
Get full text

Abstract

The highly contagious nature of the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2), the causative agent of Coronavirus Disease 2019 (COVID-19), requires rapid diagnostic tests to prevent the virus from spreading within hospitals and communities. Reverse transcription followed by the polymerase chain reaction (RT-PCR) test is the gold standard for detecting SARS-CoV-2 infections but is time-consuming, labor-intensive, and restricted to centralized laboratories. There is a growing need to develop and implement point-of-care and rapid tests for SARS-CoV-2 detection to address these limitations. We aimed to evaluate the performance of BioFire Film Array Respiratory Panel 2.1 (BioFire FA-RP2.1) for SARS-CoV-2 detection in a pediatric hospital setting. The BioFire FA-RP2.1 test provides rapid results and can identify several viral and bacterial infections in a single test. This prospective, cross-sectional, diagnostic accuracy study enrolled participants ranging from 0 to 18 years of age, seeking medical consultation for any reason, who had been in contact with individuals confirmed to have COVID-19 or managed at the hospital for medical or surgical reasons. We employed a systematic sampling technique to ensure a representative sample. The study included 339 participants with a median age of 5 years. The BioFire FA-RP2.1 test detected SARS-CoV-2 in 18.6% of cases, while the reference RT-PCR test in 14% of cases. The BioFire FA-RP2.1 sensitivity and specificity for SARS CoV-2 detection were 98% and 94%, respectively. The positive probability coefficient (LR+) was 18. The agreement between the two tests was 0.80. In addition, the BioFire FA-RP2.1 test detected coinfection with two viruses in 7,6% of cases. The BioFire FARP2.1 is a reliable solution to meet pediatric healthcare needs and improve prognosis in the post-pandemic era thanks to its friendly interface and rapid testing process.

Cite

CITATION STYLE

APA

Ramirez, M. M., Zarate, M. N., Rodriguez, L. A., & Aquino, V. H. (2023). Performance evaluation of Biofire Film Array Respiratory Panel 2.1 for SARS-CoV-2 detection in a pediatric hospital setting. PLoS ONE, 18(10 October). https://doi.org/10.1371/journal.pone.0292314

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free