Abstract
Series of mathematical phantoms of human body, given by Oak Ridge National Laboratory (ORNL), was programmed as input files for MCNP-4B code. Detailed check of geometry of these phantoms performed by MCNP-4B, discovered some minor errors, that resulted in overlapping of some organs. Three types of errors were found and described here: (a) colon overlaps with pelvis bone; (b) facial skeleton penetrate the head skin, and (c) esophagus overlaps with stomach. These errors prevent correct execution of program. Proposal for correction of these errors are given in this paper.
Cite
CITATION STYLE
Krstic, D., & Nikezic, D. (2011). Debugging of ORNL series of mathematical phantoms of human body. Acta Physica Polonica A, 119(3), 279–281. https://doi.org/10.12693/APhysPolA.119.279