Use of mitomycin C to reduce the incidence of encapsulated cysts following ahmed glaucoma valve implantation in refractory glaucoma patients: A new technique

27Citations
Citations of this article
15Readers
Mendeley users who have this article in their library.

This article is free to access.

Abstract

Background: To evaluate the surgical outcome of Ahmed glaucoma valve (AGV) implantation with a new technique of mitomycin C (MMC) application. Methods: This is a retrospective study. All patients with refractory glaucoma underwent FP-7 AGV implantation. Two methods of MMC application were used. In the traditional technique, 6 x 4 mm cotton soaked with MMC (0.25-0.33 mg/ml) was placed in the implantation area for 2-5mins; in the new technique, the valve plate first was encompassed with a thin layer of cotton soaked with MMC, then inserted into the same area. A 200 ml balanced salt solution was applied for irrigation of MMC. The surgical success rate, intraocular pressure (IOP), number of anti-glaucoma medications used, and postoperative complications were analyzed between the groups. Results: The surgical outcomes of two MMC applied techniques were compared. The new technique group had only one case (2.6%) of encapsulated cyst formation out of 38 eyes, while there were eight (19.5%) cases out of 41 eyes the in traditional group. The difference was statistically significant (P = 0.030). According to the definition of success rate, there was 89.5% in the new technique group and 70.7% in the traditional group at the follow-up end point. There was a significant difference between the two groups (P = 0.035). Mean IOP in the new technique group were significantly lower than those of the traditional group at 3 and 6 months (P < 0.05). Conclusions: By using a thin layer of cotton soaked with MMC to encompass the valve plate, the new MMC application technique could greatly decrease the incidence of encapsulated cyst and increase the success rate following AGV implantation.

Cite

CITATION STYLE

APA

Zhou, M., Wang, W., Huang, W., & Zhang, X. (2014). Use of mitomycin C to reduce the incidence of encapsulated cysts following ahmed glaucoma valve implantation in refractory glaucoma patients: A new technique. BMC Ophthalmology, 14(1). https://doi.org/10.1186/1471-2415-14-107

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free