CT methods for measuring glenoid bone loss are inaccurate, and not reproducible or interchangeable

13Citations
Citations of this article
12Readers
Mendeley users who have this article in their library.

Abstract

Aims Glenoid bone loss is a significant problem in the management of shoulder instability. The threshold at which the bone loss is considered “critical” requiring bony reconstruction has steadily dropped and is now approximately 15%. This necessitates accurate measurement in order that the correct operation is performed. CT scanning is the most commonly used mo-dality and there are a number of techniques described to measure the bone loss however few have been validated. The aim of this study was to assess the accuracy of the most commonly used techniques for measuring glenoid bone loss on CT. Methods Anatomically accurate models with known glenoid diameter and degree of bone loss were used to determine the mathematical and statistical accuracy of six of the most commonly described techniques (relative diameter, linear ipsilateral circle of best fit (COBF), linear con-tralateral COBF, Pico, Sugaya, and circle line methods). The models were prepared at 13.8%, 17.6%, and 22.9% bone loss. Sequential CT scans were taken and randomized. Blinded re-viewers made repeated measurements using the different techniques with a threshold for theoretical bone grafting set at 15%. Results At 13.8%, only the Pico technique measured under the threshold. At 17.6% and 22.9% bone loss all techniques measured above the threshold. The Pico technique was 97.1% accurate, but had a high false-negative rate and poor sensitivity underestimating the need for graft-ing. The Sugaya technique had 100% specificity but 25% of the measurements were incor-rectly above the threshold. A contralateral COBF underestimates the area by 16% and the diameter by 5 to 7%. Conclusion No one method stands out as being truly accurate and clinicians need to be aware of the limitations of their chosen technique. They are not interchangeable, and caution must be used when reading the literature as comparisons are not reliable.

Cite

CITATION STYLE

APA

Tennent, D., Antonios, T., Arnander, M., Ejindu, V., Papadakos, N., Rastogi, A., & Pearse, Y. (2023). CT methods for measuring glenoid bone loss are inaccurate, and not reproducible or interchangeable. Bone and Joint Open, 4(7), 478–489. https://doi.org/10.1302/2633-1462.47.BJO-2023-0066.R1

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free