Feasibility of standardization of serum C-peptide immunoassays with isotope-dilution liquid chromatography-tandem mass spectrometry

35Citations
Citations of this article
22Readers
Mendeley users who have this article in their library.
Get full text

Abstract

Background: Serum C-peptide concentrations reflect pancreatic function in different clinical and diagnostic settings; however, the utility of C-peptide testing is limited by the lack of standardized commercial immunoassays. Standardization can best be done by split-sample comparison with a hierarchically higher reference measurement procedure with a set of native sera. For serum peptides, isotope-dilution liquid chromatography-mass spectrometry (ID-LC/MS) is recommended as a reference measurement procedure. Methods: We evaluated the analytical performance characteristics of an ID-LC/tandem MS procedure for measurement of serum C-peptide after a 2-step solid-phase extraction. To investigate the feasibility of this procedure for use in standardization, we also performed a method comparison with 3 representative commercial assays. Results: The ID-LC/tandem MS procedure showed maximum within-run, between-run, and total CVs on dedicated sera (C-peptide concentrations, 1.6 and 4.0 pig/L) of 2.1%, 2.5%, and 2.9%, respectively; an accuracy of 94.6%-104.1%; a minimum trueness of 98.1% (95% confidence interval, 96.2%-100.0%), and limits of quantification and detection of 0.15 and 0.03 μg/L, respectively. Deming linear regression analysis of the method-comparison data showed that the immunoassays correlated well with ID-MS and were specific, but lacked intercomparability and trueness. We propose that the deficiencies can be resolved by recalibration on the basis of the method comparison. Conclusions: The ID-LC/tandem MS procedure is suitable for specific and accurate measurement of basal and stimulated serum concentrations of proinsulin C-peptide fragment 33-63 and is suitable for use in standardization of C-peptide immunoassays. © 2006 American Association for Clinical Chemistry.

Cite

CITATION STYLE

APA

Rodríguez-Cabaleiro, D., Stöckl, D., Kaufman, J. M., Fiers, T., & Thienpont, L. M. (2006). Feasibility of standardization of serum C-peptide immunoassays with isotope-dilution liquid chromatography-tandem mass spectrometry. Clinical Chemistry, 52(6), 1193–1196. https://doi.org/10.1373/clinchem.2005.062505

Register to see more suggestions

Mendeley helps you to discover research relevant for your work.

Already have an account?

Save time finding and organizing research with Mendeley

Sign up for free